ethernet/ip to modbus serialplx31-eip-mbsprosoft technology’s ethernet/ip™ to modbus® serial communication gateway allows high-speed bi-directional data transfers between ethernet/ip™ pacs or devices and modbus®-enabled pacs or devices.
ethernet/ip™ pacs include rockwell automation® controllogix® and compactlogix™, as well as several schneider electric® controllers. modbus® serial devices are widely used in nearly every industry and include scada systems and power monitors.
the gateway includes several features that allow for simplified integration, reduced commissioning time and optimized performance
※※※ 深圳市扎克貿(mào)易有限公司
※※※ 張瑞 188-24-24-3080(v同)
※※※ q:306-167-1820
specificationsethernet/ip™ specifications
specification
description
number of class 3 server connections
5
supported plc types
plc2, plc5, slc, clx, cmplx, microlx
supported message types
pccc and cip
class 3 client connections
connected: 2unconnected: 1
number of class 1 i/o connections
2
i/o connection sizes
248/248
max rpi time
5 ms per connection
cip services supported
0x4c - cip data table read0x4d - cip data table writecip generic
command list
support for 100 commands per client, each configurable for command type, ip address, register to/from addressing and word/bit count.
command sets
plc-2/plc-3/plc5 basic command setplc5 binary command setplc5 ascii command setslc500 command set
modbus serial specifications
specification
description
command list
up to 100 commands per master port, each fully configurable for function code, slave address, register to/from addressing and word/bit count.
supported modbus function codes
1: read coil status2: read input status3: read holding registers4: read input registers5: force (write) single coil6: preset (write) single holding register
15: force (write) multiple coils16: preset (write) multiple holding registers22: mask write holding register (slave only)23: read/write holding registers (slave only)
software configurable communication parameters
baud rate: 110 baud to 115.2 kbps parity: none, even, odd data size: 7 or 8 bits stop bits: 1 or 2 rts on/off delay: 0 to 65535 millisecondsmodbus rtu mode (binary) with crc-16modbus ascii mode with lrc error checkingfloating point data floating point data movement supported, including configurable support for enron and daniel implementations
polling of command list
configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.
status data
error codes available on an individual command basis. in addition, a slave status list is maintained
node address
1 to 247 (software selectable)
rs interface
rs232, rs422, and rs485
transmit and receive buffer size
255 byte transmit character length with 0 to 65535 millisecond delay between each transmitted character